Create a Drag Truss
Before you begin, select a profile truss, such as a Common truss.
A drag truss carries an in-plane (lateral) force, a drag load, from the roof or floor diaphragm into a shear wall below. You add the drag load in the truss's load settings, choose where the truss is connected to resist it, and Paragon Design analyzes the truss for the load in both directions. Drag loads work on roof and floor trusses. For what each setting does, see the Load Settings Reference.
Step 1 - Click Truss Settings and choose Load Settings
Truss Settings is the gear icon in the top toolbar.

Step 2 - Check Drag Loads
Checking the box turns drag loads on for the truss and expands the section.

Step 3 - Enter a drag load, such as 1500 in Total Drag Load
The drag load comes from the building's lateral design. Use the value on the plans or from the building designer.
Step 4 - Choose a unit, such as Pounds for Drag Load Unit
Pounds is the total force on the truss. Plf is a load per foot, which Paragon Design multiplies by the top chord's horizontal span to get the total.
Step 5 - Choose between Top Chord and Bottom Chord for Chord to resist on
This is where the truss is connected to resist the drag load. With Top Chord, you choose the end it's taken out at, Left or Right, in Side to resist on (for top chord), and the bottom chord restraint locations don't apply.

Step 6 - Enter where the bottom chord restraint starts, such as 0 in Start
With one truss selected, Bottom Chord Horizontal Restraint Locations lists each length of bottom chord that's connected to resist the load. Its switch sets whether Start and End are measured from the left or the right end of the truss. The list doesn't appear when you've selected several trusses.
Step 7 - Enter where it ends, such as 10' in End
Paragon Design doesn't let a restraint be too short for the load to be applied to it.
Step 8 - Click Change settings for this component
Drag DOL, in the same section, sets the load duration factor for the drag load cases.
When the truss is analyzed, the drag load is applied in both directions, so the load cases include a Drag Load Right and a Drag Load Left case. On a roof truss with wind loads on, they're combined with dead and wind loads. On a floor truss, they're combined with dead and floor live loads. A Dead + Drag Load Right and a Dead + Drag Load Left pair is also added when wind loads are off, or when the drag DOL is lower than the wind DOL (roof) or the floor live DOL (floor).
The truss's design notes say the total drag load it's designed for and where to connect it: along the bottom chord between the restraint locations, with the load per foot, or at the chosen end of the top chord.